AT26x dual channel strain gauge measuring amplifier

  • Meets performance level C for use in safety-related applications
  • Comprehensive monitoring functions
  • control panel and display using a 7 segment display
  • Alarms emitted via relay outputs

Application

AT265/266/267 strain gauge measuring amplifiers are used to capture signals from two strain gauge bridges and provide current values and status information for further processing at automation level. Strain gauge sensors deliver a signal proportional to the applied force which is captured by the measuring amplifiers and provided as an analogue signal (adjustable 0.4…20 mA or 0 – 10v). At the same time adjustable signal limits are monitored and if they exceed or fall below the set limit, this is notified as an alarm via potential-free relay contacts. In addition, the measuring amplifiers have comprehensive monitoring functions for cable breaks, short circuit, hardware errors, power supply etc. which enable the highest level of operational safety.

The AT265/266/267 strain gauge measuring amplifier range is suitable for performance level C in safety-related applications.

Possible areas of use:

  • Melt pressure monitoring for extruders
  • Load monitoring in materials handling technology
  • Force and pressure monitoring in mechanical engineering
  • Weighing equipment

 

Display and operation

The modules have a three digit 7 segment display to show measurement values, adjustable parameters and status displays. Important status information is also displayed by 6 differently coloured LEDs on the front of the module. The modules are operated by a plastic film keyboard with 4 keys.

 

Output signals

Analogue voltage or power outputs are available in each case to output measurement values from the two strain gauge sensors. An alarm or a warning occurring is indicated by two separate potential-free contacts and also two 24v digital outputs. All connections are fed through to coded plugs on the front.
Your benefits

  • Suitable in safety-related applications with performance level C.
  • Comprehensive monitoring functions for maximum operational safety.
  • Easy to configure
  • Digital I/O connection to the PLC
  • Configurable alarm system

 

AT265 – with redundant measurement value recording

The AT265 monitors two pressure sensors that must be fitted in practically identical positions for redundant monitoring of pressure values occurring in the machine.

An alarm is emitted, amongst other things, when a set maximum differential measurement value between the two measurement value recorders is exceeded.

AT266 – classic dual channel measurement amplifiers

The AT266 has 2 measuring channels for strain gauge sensors that are independent of each other. Each sensor has an analogue output for measurement value output and a relay contact to notify alarms.

AT267 with cumulative measurement value output

The AT267 monitors two strain gauge sensors and provides the total signal on the analogue output. An alarm is emitted amongst other things if the total of the two measurement values exceeds a limit value or the difference between the two signals deviates too much from each other (unbalanced load).

Dual channel strain gauge measuring amplifiers
Dual channel strain gauge measuring amplifiers-classic
Dual channel strain gauge measuring amplifiers with accumulated measured value output
Product type

AT265

AT266

AT267

Number of DMS sensor measuring inputs

2

2

2

Resolution

16 bit

16 bit

16 bit

Accuracy

max. 0,065% of FSR

max. 0,065% of FSR

max. 0.065% of FSR

Analogue voltage outputs

0 to 5/10V can be configured

0 to 5 / 10V can be configured

0 to 5 / 10V can be configured

Analogue current outputs

0/4 to 20mA can be configured

0/4 to 20mA can be configured

0/4 to 20mA can be configured

Display

3 digit 7 segment

3 digit 7 segment

3 digit 7 segment

Digital outputs (alarms)

2

2

2

Digital inputs

4

4

4

Pressure transducer supply

10V

10V

10V

Housing dimensions (WxHxD)

53 x 116 x 125 mm

53 x 116 x 125mm

53 x 116 x 125mm

Power consumption

5W

5W

5W

Assembly

DIN standard rail mounting

DIN standard rail mounting

DIN standard rail mounting

Performance level according to EN ISO 13849-1

c

C

C

Relay outputs (alarms)

2x 250VAC, 2A

2x 250VAC, 2A

2x 250VAC, 2A

Supply voltage

24VDC

24VDC

24VDC

Operation

Display

3x 7- segment display

Film keyboard keys

4

Power supply

24VDC

Power consumption

max. 5W

Strain gauge bridges

Number of zones

2

Measurement bridge supply

10VDC stable/max. 120mA per sensor

Input sensitivity

1mV/10V ... 100mV/10V

Zero point/ Amplification

Adjusts automatically with calibration

Outputs

Voltage output

0-10VDC or 0-5VDC can be selected

Current output

0-20/4-20mA can be selected or
extended according to NAMUR NE43 3.6-21mA

Alarms

Hysteresis alarms

adjustable

Potential-free alarm relay

2x 250VAC, 2A

Digital alarm output

2x 24VDC, 12mA

Delay

adjustable

Inputs

Digital inputs

4

Analogue inputs

2x 6 pin strain gauge input

Housing/ Assembly

Dimensions W/H/D

53 x 116 x 125mm

Weight

550g

Housing material

Metal

Protection class

IP20

Attaching parts

Snap fastener for TS35 mounting rail

Operating temperature

0 ..50°C, no condensation

Information material

Description
Data file
AT267 manual
AT266 manual
AT265 manual